Abdel Karim, Nabil
(Notre Dame University-Louaize, 2018-06)
In wind turbine generating systems, Axial Flux Permanent Magnet Synchronous
Generators (AFPMSG) are becoming increasingly popular due to many advantages
they offer. Nevertheless, these machines suffer from the so-called cogging torque
resulting from the interaction between the permanent magnets and the slotted
armature. Not only it causes noise and vibration, this cogging torque affects the selfstart
ability of wind turbines at low wind speed. Therefore, the aerodynamic torque
•generated by the rotor blades should overcome the cogging torque anytime during the
operation otherwise the wind ...