Institutional Repository

The stress strain response of concrete laterally confined with low and high performance fiber-reinforced cements and polymer composites : a comparative experimental and theoretical study

Show simple item record

dc.contributor.author Sarieldine, Rawan Osmat
dc.date.accessioned 2020-09-29T08:44:14Z
dc.date.available 2020-09-29T08:44:14Z
dc.date.issued 2020
dc.identifier.citation Sarieldine, R. O. (2020). The stress strain response of concrete laterally confined with low and high performance fiber-reinforced cements and polymer composites : a comparative experimental and theoretical study (Master's thesis, Notre Dame University-Louaize, Zouk Mosbeh, Lebanon). Retrieved from http://ir.ndu.edu.lb/123456789/1220 en_US
dc.identifier.uri http://ir.ndu.edu.lb/123456789/1220
dc.description M.S. -- Faculty of Engineering, Notre Dame University, Louaize, 2020; "A thesis presented in partial fulfillment of the requirements for the degree of Master of Science in Civil Engineering."; Includes bibliographical references (pages 111-113). en_US
dc.description.abstract While concrete, steel and Fiber Reinforced Polymer (FRP) jackets are the most commonly used types of jackets in the industry to confine columns, the focus of this research is to study and compare the compressive behavior of concrete cylinders confined with different types of fibrous composites; including Fiber Reinforced Concrete (FRC), Fiber Reinforced Mortar (FRM), and Slurry Infiltrated Fiber Concrete (SIFC). This study will provide a broad understanding of the behavior of the different confinement types used to retrofit columns to resist detrimental loads including blast and impact. The study will compare the compressive stress-strain response of different fibrous confinements to the commonly used ones such as FRP and spirals (SP), by developing empirical models to be used in design. The confinements are classified as either continuous or discrete. Continuous confinement is when the composite is wrapped continuously around the structural members such as FRP, FRC, FRM, and SIFC while in discrete confinements they are spaced at a specific pitch such as spirals (SP) and wire mesh (WIM).The purpose of studying different types of fibrous confinements such as FRC and SIFC is to better understand their response with respect to the continuity and orientation of fibers. As for studying WIM confinement, was to understand the effect of two-fiber orientation as well as their interaction (WIM being the “bounding” case with “fibers” being oriented only in the vertical and the horizontal direction).The ultimate goal of this research is to investigate, understand, and develop the overall stress-strain and load-displacement (i.e. resistance and ductility) response model of columns confined with different fibrous composites. The developed compressive stress-strain behavior will be compared to the exiting Spiral Reinforcement (SP) and FRP confinement used commonly in the industry, to be able to select the most suitable, and appropriate retrofit technique, and to be able to design from an engineering standpoint. This research is achieved through an experimental and analytical investigation Models developed in this work have shown good agreement with experimental data. High Performance Fiber Reinforced Concrete (HPFRC) jackets made with continuous fibers exhibited debonding and multiple cracking leading to softening effects beyond peak and higher strains at rupture, which translates into an increase in ductility, and energy dissipation of the confined column. Varying orientation of fibers in FRC and FRM jackets produce radial tensile stresses on the concrete core resulting in partial confinement, thus weakening the concrete core and developing peak stresses lower than unconfined concrete. However due to fiber pull-out, they have higher ductility and maintain softening effects beyond peak and rupture strains better than unconfined concrete. en_US
dc.format.extent xiii, 150 pages : illustrations (some color)
dc.language.iso en en_US
dc.publisher Notre Dame University-Louaize en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject.lcsh Fiber cement
dc.subject.lcsh Industrial engineering
dc.subject.lcsh Construction industry
dc.subject.lcsh Building materials
dc.title The stress strain response of concrete laterally confined with low and high performance fiber-reinforced cements and polymer composites : a comparative experimental and theoretical study en_US
dc.type Thesis en_US
dc.rights.license This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 United States License. (CC BY-NC 3.0 US)
dc.contributor.supervisor Malak, Sary, Ph.D. en_US
dc.contributor.department Notre Dame University, Louaize. Department of Civil and Evironmental Engineering en_US